A 5,000 square foot warehouse addition.
The building had to meet Greenfield’s demanding stretch energy code requiring “High R” roof and wall insulation systems. The roof is a standing seam Double-Lok system with an R-32 PurlinGlide roof insulation system. The walls were constructed utilizing an IPP-II 2.5 inch thick insulated panel achieving an R-20 insulation value.
JLN provided steel design, a Star pre-engineered steel building and steel erection for the project.